处cpAPP改成什么名字了,跟处cp一样污的软件

小仙女直播改名了,小仙女s app

Floor insulation and sound insulation board customized by Shenghao manufacturer, high quality and low price

Time: May 9, 2019
Hefei Shenghao thermal insulation materials Co., Ltd. address: building 39, G District, Jiahai Industrial Park, 500m south from the intersection of Guhe road and Jingshan Road, Changfeng County, Hefei City, Anhui Province. As a professional manufacturer of floor insulation and sound insulation board, we ensure that every link in the production process can be traced through the perfect quality control system. Internal strict inspection layer by layer screening to ensure that the quality of graphite EPS insulation composite board is qualified. Through scientific and rigorous construction technology, to ensure compliance with the regulations and standards. Graphite polystyrene board has good fire resistance.
 
Graphite polyphenylene board has good fire resistance, and the effect of thermal insulation is also very obvious. So what kind of advantages does graphite polyphenylene board have in heat preservation? Today from the two aspects of graphite polyphenylene board to let you know, first of all, compared with other thermal insulation materials, graphite polystyrene board has stronger insulation capacity. Graphite polyphenylene board is the product of classic heat insulation material expanded polystyrene which is further refined by chemical method, and its heat insulation performance has been improved obviously. It contains special graphite particles, which can reflect thermal radiation like a mirror, and it contains infrared absorber which can greatly improve the thermal insulation performance, so as to reduce the heat loss of the house. Secondly, in the construction process, the amount of graphite polystyrene board with the same effect is less than that of conventional EPS insulation board. Graphite polystyrene board in addition to fire insulation performance is better than other thermal insulation materials, but also can reduce the environmental burden, green environmental protection and other advantages! It is a good choice for modern building insulation materials! Construction regulations of floor insulation board: 1. The thickness of insulation board should be determined according to thermal calculation and sound insulation requirements, but it should not be less than 15mm. If the floor heating water pipe is set in the concrete protective layer, the thickness of the insulation and sound insulation board shall not be less than 25 mm. 2. The concrete cover is generally poured with fine aggregate concrete, and the strength grade should be C25 (the actual construction is C20). The thickness shall not be less than 40mm; when the floor heating water pipe is set in the protective layer, the pea stone concrete shall be used, the strength grade shall be C15, and the thickness shall not be less than 50mm. 3. When the ground area is more than 30m2 or the side length is more than 6m, the concrete cover should be set with expansion joints at the spacing of no more than 6m. The width of expansion joint should be 20 mm, and grade B1 graphite molding polystyrene board can be filled in the joint.
Detailed rules for construction scheme of floor insulation board 1. Construction scheme shall be prepared before construction, and construction personnel shall be trained and technical disclosure shall be conducted. 2. The heat insulation and sound insulation board and supporting materials shall be protected from sun and rain during storage and transportation. It is strictly forbidden to stack them in the open air. They must be stored indoors. The boards should not be placed horizontally or directly contact the ground. They should be stacked vertically on the flat and dry supporting blocks. They should be handled with care during transportation. 3. The construction of thermal insulation and sound insulation system of building floor can be carried out only after the base floor or ground plain concrete cushion is completed and passed the inspection. 4. The ambient temperature during construction shall not be less than 5. 5. The finished products shall be well protected after the vertical sound insulation sheet is pasted, the insulation board is laid, the waterproof tape is pasted and the concrete protective layer is poured.
Hefei Shenghao thermal insulation material Co., Ltd. is committed to the research and application of acoustic materials and acoustic engineering, providing users with better acoustic system treatment scheme. Welcome new and old customers to visit our factory.